Cambridge Technologies |
---|
Part Number: B0801401-16
M22759/34-10-9 Normal Weight Wall Cross-Linked ETFE Wire Insulation: Dual Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/34); Silver Plated High Strength Copper Alloy (/35) Operating Temperature: 150 deg C/200 deg C Operating Voltage: 600 Volts...
Part Number: B0801402-22
M22759/34-10-9 Normal Weight Wall Cross-Linked ETFE Wire Insulation: Dual Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/34); Silver Plated High Strength Copper Alloy (/35) Operating Temperature: 150 deg C/200 deg C Operating Voltage: 600 Volts...
Part Number: M27500-10-TG-1-T14
M27500 TG and TH cables are shielded and jacketed cables with extruded ETFE (Ethylene Tetrafluoroethylene) jackets, incorporating MIL-W-22759/18 or /19 wires. These component wires are insulated with thin-wall extruded ETFE for weight and space savings, and have either tin-plated copper or silver-plated high-strength copper alloy conductors. Performance: Voltage...
Part Number: M27500-10-TG-2-T14
M27500 TG and TH cables are shielded and jacketed cables with extruded ETFE (Ethylene Tetrafluoroethylene) jackets, incorporating MIL-W-22759/18 or /19 wires. These component wires are insulated with thin-wall extruded ETFE for weight and space savings, and have either tin-plated copper or silver-plated high-strength copper alloy conductors. Performance: Voltage...
Part Number: M22759/34-10-0
"M22759/34-10-9 Normal Weight Wall Cross-Linked ETFE Wire Insulation: Dual Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/34); Silver Plated High Strength Copper Alloy (/35) Operating Temperature: 150 deg C/200 deg C Operating Voltage: 600 Volts...
Part Number: M22759/34-10-2
"M22759/34-10-9 Normal Weight Wall Cross-Linked ETFE Wire Insulation: Dual Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/34); Silver Plated High Strength Copper Alloy (/35) Operating Temperature: 150 deg C/200 deg C Operating Voltage: 600 Volts...
Part Number: M22759/34-10-9
"M22759/34-18-9 Normal Weight Wall Cross-Linked ETFE Wire Insulation: Dual Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/34); Silver Plated High Strength Copper Alloy (/35) Operating Temperature: 150 deg C/200 deg C Operating Voltage: 600 Volts...
Part Number: M22759/43-10-9
M22759/43-10-9 Normal Weight Wall Cross-Linked ETFE Wire Insulation: Dual Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper Operating Temperature: 150 deg C/200 deg C Operating Voltage: 600 Volts Download pdf of this page...